	| I accept a call about consultation and estimate about a flowmeter.Please 
	feel free to inquire from a phone. TEL:06(6855)1126
 FAX:06(6855)1129
 
 |   |  
      
 
	 
	| The flow meter will produce by order 
	based on the condition used. In the case of an estimate, please direct the measured fluid name, range of flowing 
	quantity, pressure, temperature,etc.
 
 
 When the liquid of the water corresponding is measured, it is of no matter, but 
	we be designed and product with specific gravity and viscosity. A temperature 
	variation is a big influence is exerted on the display of flowing quantity, so 
	please keep a fixed temperature as much as possible. It 
	is necessary for measuring liquid (specific gravity and viscosity).
 
 we will set the condition of the measured gas (pressure and temperature) and produce It 
	is necessary for measuring gas (pressure and temperature).
the flow meter for the gas.
 The flow quantity becomes flow quantity converted into normal condition (atmospheric 
	pressure 20 degrees Celsius).
 In addition, we produce even a standard state (atmospheric pressure 0 degrees 
	Celsius) by a demand.
 
 
  Fig. 
	A, pressure 0.3MPa joins the needle valve and figure A becomes a state (atmospheric 
	pressure) without pressure drag after it.Setting pressure is atmospheric pressure 
	(1atm). 
 Fig. B, Pressure 0.3MPa joins the flow meter and the needle valve, and even when 
	be that the atmospheric pressure or some load pressures joins after that, set 
	pressure becomes 0.3MPa.
 
 Please always do setting pressure in the state that constant pressure hung over 
	to a flowmeter by pressure when gas to measure passes by in a flowmeter.In addition, 
	when pressure and the temperature change, it will correct it by the value of fluctuations.
 
 
 The principle of accuracy is within based on JIS ア2%- ア5% of maximum scale value 
	(F.S). However, accuracy might decrease when it is the following. Precision
 
	Minute flow quantityLiquid of high viscosityGas with extremely small density 
 
 It does by the pressure 1.5 times the maximum use pressure. Withstand pressure/ leakage inspection
 
  Flow correction formula
Liquid correction formula
		 
		| When the density is different in the different kind liquid |   
		|  |  |  Different kind gas, Pressure and temperature correction formula
		 
		| When the unit of pressure is kPa |   
		|  |  |  
		 
		| When the unit of pressure is kgf/cm2(G) |   
		|  |  |  Steam correction formula
		 
		|  |  |   
		| *In general, the steam shows Mass(weight) by the unit |  
 Explanation of sign
		
		 
		|  | Q | : | True flow quantity |   
		|  | q | : | Flow quantity on a dial |   
		|  | ρf | : | Density of a float |   
		|  | ρ0 | : | Density of a fluid on a dial |   
		|  | ρ1 | : | Density of a different fluid |   
		|  | P0 | : | Pressure (kPa/kgf/cm2G) on a dial |   
		|  | P1 | : | Different pressure (kPa/kgf/cm2G) |   
		|  | T0 | : | Temperature on a dial |   
		|  | T1 | : | Different temperature |   
		|  | W1 | : | True flow quantity (mass) |   
		|  | W0 | : | Flow quantity (mass) on a dial |   
		|  | γ0 | : | Density of steam on a dial |   
		|  | γ1 | : | Density of different steam |  |  
 
 
	
	|  |  |  |